range Acti 9 product name Disbo iC60 product or component type Miniature circuit-breaker device short name IC60N poles description 2P number of protected poles 2 [In] rated current 32 A network type AC/DC trip unit technology Thermal-magnetic curve code C breaking capacity 6 kA Icu at 100...133 V DC conforming to EN/IEC 60947-2 6000 A Icn at 415 V AC 50/60 Hz conforming to EN/IEC 60898-1 36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 utilisation category Category A conforming to EN/IEC 60947-2 Complementary network frequency 50/60 Hz [Ue] rated operational voltage 440 V AC 50/60 Hz magnetic tripping limit 8 x In +/- 20 % [Ics] rated service breaking capacity 27 kA 75 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 75 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 6000 A 100 % conforming to EN/IEC 60898-1 - 415 V AC 50/60 Hz 6 kA 100 % conforming to EN/IEC 60947-2 - 100...133 V DC limitation class 3 conforming to EN/IEC 60947-2 [Ui] rated insulation voltage 500 V AC 50/60 Hz [Uimp] rated impulse withstand voltage 6 kV conforming to EN/IEC 60947-2 contact position indicator Yes control type Toggle local signalling Trip indicator mounting mode Clip-on mounting support Rail 9 mm pitches 4 height 85 mm width 36 mm depth 78.5 mm net weight 0.25 kg colour White mechanical durability 20000 cycles electrical durability 10000 cycles provision for padlocking Padlockable connections - terminals Single terminal (top or bottom) 1…35 mm² rigid Single terminal (top or bottom) 1…25 mm² flexible wire stripping length 14 mm for top or bottom connection tightening torque 3.5 N.m top or bottom earth-leakage protection Separate block Environment standards EN/IEC 60898-1 EN/IEC 60947-2 IP degree of protection IP20 conforming to IEC 60529 pollution degree 3 conforming to EN/IEC 60947-2 tropicalisation 2 conforming to IEC 60068-1 relative humidity 95 % at 55 °C ambient air temperature for operation -35…70 °C ambient air temperature for storage -40…85 °C